BILT Speaker

BILT Speaker
RevitCat - Revit Consultant
Showing posts with label property. Show all posts
Showing posts with label property. Show all posts

Saturday, 17 April 2021

Cut with Voids When Loaded - 'Cuts Geometry' Postscript

Following my earlier blog post on Cut with Void When Loaded in Revit, I have discovered another subtle exception to the rule:

It does not work properly with the new Revit 2021 feature "Void Cuts in Family Geometry" that allows you to turn the 'cutting capability' voids on/off in a family.  NB. This is sometimes referred to as turning off Void visibility, which is misleading.

Void in Family Editor

Here is a workflow that demonstrates the confusing behaviour:

  • In the family editor, create a new Generic Model family
  • Tick the 'Cuts with Void When loaded' family property
  • Create a solid with two more intersecting solids
  • Change the two outside solids to voids 
  • The voids will not cut the solid - this is a deliberate technique to carefully control what cuts what
  • Use the 'Cut' command to cut one of the voids from the solid (only one)
  • Select the visible void and link its 'Cut Geometry' property to a parameter - say "Cut Rect"
  • Select the invisible void (that is cutting the solid)
  • link its 'Cut Geometry' property to another parameter - say "Cut Cylinder"
  • In theory, this should allow you to turn off 'cutting capability' of each void independently, once in the project - and hence whether they cut or not.

Test this in the Family Editor

  • With both voids 'cuttable', the cylinder cuts but the rectangular void does not (as expected) - this is because the rectangular void was never told to cut the solid, so it has no effect in the family


  • Turn off the 'cutting capability' of the cylinder - it no longer cuts the solid;  it actually becomes visible, which may seem contradictory - but that is typical Revit behaviour (voids not cutting anything show orange;  voids already cutting a solid disappear)

Switch the cutting properties around so the cylinder can cut but the rectangular cannot - visually it looks the same as having both properties ticked.


 Voids in the Project

From my earlier blog post on Cut with Void When Loaded in Revit, we know that in order for it to work in a project, the cutting void must be set to not actually cut anything in the family - as the rectangular void is set up.
 
  • Load the family into a project

  • Place the family onto an element that it intersect with
  • Both 'Cut Geometry' checkboxes ticked

  • Untick both checkboxes, so the cylinder void is no longer cutting the family solid (rectangular void does not cut it regardless)
  • Both voids are ghosted when the family is selected, or in pre-selection

  • Use the project 'Cut geometry' command with the host element and family
  • Both voids will cut the host element (neither void is cutting the family solid)


  • Tick the 'Cut Rect' checkbox -
    • The cylinder is not cutting the family solid, so it cuts the host element in the project (this may not be what you want, but it cannot be avoided!)
    • the rectangular void is not cutting the family void, so it cuts the host


  • Tick both boxes - only the rectangular void cuts the host (as it is not cutting the family solid)
    • The cylinder now cuts the family solid but not the host (and is no longer visibly ghosted)

Conclusion

  • If the void cuts a solid in the family, it cannot cut an element in the project using the 'Cuts with Void When loaded' family property
  • If the void cuts a solid in the family,the new (in v2021) 'Cut Geometry' property has the potential to work in a project
  • If the void does not cut a solid in the family, it can cut an element in the project using the 'Cuts with Void When loaded' family property - but only when you use the 'Cut' command in the project
  • If the void does not cut a solid in the family,the new (in v2021) 'Cut Geometry' property has absolutely no effect in the project

This probably makes sense if you think really hard about decisions the programmers had to make about what is possible and how it might work.

However, it is mighty confusing for the end user.

To make matters worse, we now have two entirely different 'Cut Geometry' functions in Revit:

  • 'Cut Geometry' property in the family - a checkbox
  • 'Cut Geometry' command:
    • in the family- where you actively select which elements cut each other
    • in the project - where you actively select which family cuts which element but the results depend on all kinds of things in the family (as described above).

All clear now?  Or still confused?




Monday, 20 April 2020

System Volume Parameter in Generic Category Families

 Here in New South Wales, Australia, we have a planning requirement (SEPP65) to provide a certain amount of storage in multi-unit residential developments.  Some of that storage can be in the apartment itself, and some can be in storage cages/cupboards in the basement.

The storage has to be calculated by volume per apartment - this means that we have to create schedules that combine the storage cupboards in apartments with the cages in the basement.  Thus we need to create objects of different shapes and sizes in the model.

There are several ways to calculate the volumes from these objects, but surely the simplest way would be to use Revit's automatic volume calculation properties?

System Volume Property

You would think that Revit would be able to report back the volume of any object in your model.  It is a database, right?

It turns out that it can do so, to a very limited extent - and of course that leads to restrictions and frustrations.

It seems that only cetain category objects can report their volume, and then there may be further restrictions on scheduling or tagging:

By Category

  • Many of the system families do have a "Volume" property

  • But you would not want to create storage cages or cupboards by mis-using those categories?  No, you would not!
  • Logically you would use the Casework category for cupboards - but sadly that category does not have a volume property.
  • The same applies for most loadable family categories.

  • You could use the Mass category, but that is not sensible either, because that should be reserved for creating building massing models - if you start mis-using that category it will surely make life difficult (not least with visibility issues).

  • Rooms do have volume properties, although that can depend on project settings - see below.
  • Rooms are also not an ideal way to model such things as high-level storage cupboards!

  •  That leaves us with one last option (that I know of):  the Generic category.
  • For many years in Revit, generic families did report a Volume property (automatically calculated from the volume of all solid objects in the family).
  • However, it was not originally possible to schedule this property
 
  • In Revit 2014, Autodesk enabled the ability to schedule this Volume property.
  • This was one of my few successes with lobbying Autodesk to include one small new feature in Revit, that would make a big difference to us.
  • Sadly they ignored my pleas to also enable this property to be tagged.

Generic Families

Prior to v2014, we created a range of storage families that did the volume calculations as formulas within the families - so that we could schedule and tag the volumes.

When it comes to basement storage cages, the shapes often become quite complex as they have to wrap around columns or need angled sides.


This led to some quite complex formulas that needed to take into account optional cutouts to the shapes, and to allow for overlapping cutouts.





Fortunately all these calculations became redundant with v2014, as we can now use the system calculated "Volume" parameter to schedule storage volumes.

Except . . . . . When a project requires the storage to be tagged on drawings.

Room Volumes

Rooms do have the ability to calculate and report their volume, and it may be easier to create basement storage cages as rooms with cage walls to enclose them.  This would allow any shaped area without having to create a range of families.


However, this becomes problemmatic when you need to create one schedule that combines the basement storage cages (Rooms) with in apartment storage cupboards (Generic category families).

Room volume calculations also have some quirks, that depend on project-wide settings:

  • Rooms have a height property - this is used for the system calculated volume.
  • However, it will not work if Rooms are set to only calculate Areas (not Volume)
  • This project-wide setting is generally recommended as it makes the project performance noticeably faster - the menu even tells you that (and it is true)

  • If you enable Areas and Volume calculation you will get the volumes being reported, but a slower project.
  • If you need to do this anyway, then it is no extra overhead for calculating room storage.




Room Volumes are calculated at Wall Finish, regardless of the Room Area settings.
  • This can be complicated if you need room areas to be calculated to wall centrelines.
  • More on this in another blog post . . . .

Monday, 3 February 2020

Room Bounding Structural Column Materials in Revit


I recently discovered yet another obscure, hidden away setting in Revit - when I was investigating the "Room Bounding" property of different elements.

It seems that some structural columns have a "Room Bounding" property - but not all.
This has to be one of the weirdest, arbitrary decisions made by the Revit programmers:

Material for Model Behaviour

Structural columns have a weird property - so obscure and arcane, not to mention hidden away.
'Material for Model Behavior'

This property that can only be set in the Family Editor – in ‘Family Category and Parameters’: ‘Material for Model Behaviour’.


It can be one of 5 settings, each of which enables different properties and behaviour in the model:
  • Steel
  • Concrete
  • Precast Concrete
  • Wood
  • Other
Depending on which one you choose, it will enable properties in the family.
  • Steel has Connection properties
  • Concrete & Other have Rebar properties
 

These settings are hidden away behind the 'Family Category and Parameters' settings - in the project there is no way to tell which setting the family has, apart from the specific properties displayed.

You would have thought that this only affects structural engineers?

But wait.  It affects architects too . . . . .
  • Concrete has ‘Room Bounding’ properties (it is the only one that does)


Why, oh why are wood and precast concrete not room-bounding?  There are a huge number of timber structures around the world that provide perfectly good enclosures.
Wouldn't it just have been easier to make all columns potentially enclose rooms, instead of hard-coding someone's bizarre ideas about how a building might work?

Room-Bounding

When working in a project, and you discover that a 'Room' is not enclosed when you expect it to be, this is one of many things to check.
There are some other quirky Room-Bounding behaviours in Revit, to be detailed later  . . .

Monday, 13 January 2020

Levels By Scope Box Hidden in Section Elevation

Lost your Levels in Revit?

Here is some weird Revit behaviour that you may need to know about Scope Boxes and Level/Grid visibility - to help you find invisible Levels:

Example: Multistorey Building with podium and  two towers 

A common situation in Revit occurs when you have two sets of levels, that do not align - perhaps you have a building with two towers that have different floor to floor heights.

NB. In this example:
  • All levels are displayed with 3D extents (so it ignores the effects of 2D view cropping of levels). 
  • Same behaviour applies to grids as levels, but only levels are shown here.

Level Visibility

  • From one direction the levels look good in elevation or section
South Elevation - Levels
  •  Looking from the side, the levels might overlap each other (depending on the view extents) - a mess where you can see both sets of tower levels mixed together.
Side Elevation - all levels visible

  • To make the side elevations and cross-sections look better, you need to adjust the view extents -

  • Typically you should set 'Far Clipping' to 'Clip without line' and set the offset so that it extends into the levels that you want to see, but not the distant ones
South Elevation - Far Clipping through levels
Section - Far Clipping through levels

  •  If the clipping is too short you won't see the levels
South Elevation - Far Clipping too short
Section - Far Clipping too short
  • If the far clipping is too long, and extends through both sets of levels, they will both be displayed (usually - see Weird Stuff below)
  • If Far Clipping is set to 'No Clip', you will see all the levels
No Clip
Far Clipping Options
South Elevation - No Far Clipping
Section - No Far Clipping

  • Interestingly, when you set a section or elevation to 'No Far Clip', you can actually see levels behind the view.  In the example below, the section line is between the towers.
South Elevation - Section between towers; No Far Clipping
Section between towers - No Far Clipping

Where Are My Levels?

If some (or all) of your Revit building levels are not showing up in a section or elevation view, you can use the above 'No Clip' behaviour to your advantage:
  • Check all the usual visibility settings, such as Category On; no filters; Not hidden in view etc.

  • Set the view extents to 'No Clip'
  • Set the view to 'No Cropping', so that you can see the 3D extents of all levels

If the levels are still not visible, it may be due this next quirk of Revit behaviour:

Weird Scope Box Properties

  • If any of the levels (or grids) have a scope box applied to them, not only will the scope box crop their extents, it will also prevent levels from showing in a section or elevation unless the cutting plane of the section/elevation actually intersects the level.
  • This means that 'No Far Clipping' has no effect on visibility



To resolve this:
  • you have to set the Scope Box properties back to 'None'

  • The level extents will not change, but they will no longer be controlled or locked by a scope box.
  • You have to make a decision about which is the worst of two evils!

You may also want to check the 3D extents of levels in a 3D view by turning the Level category on in Visibility Graphics.  Refer to 3D Levels

Another Scope Box Quirk

 Scope Box visibility behaves differently to Levels and Grids:
  • A scope box will always be visible in a section or elevation view only when the view cutting plane actually intersects the scope box.
  • You cannot make distant scope boxes visible by changing the section/elevation Far Clipping property to 'No Clip' - unlike Levels, it makes no difference.

More info about Scope Boxes: